In the main menu Server -> Settings dialog, there are a set of important setting groups.

 

Main settings tab

 

Only allow local connections

Prevents remote (cross network/Internet) connections to the server.

 

Installed in a cluster environment

Check this if you are installing VisualCron on a shared drive.

 

Server port

VisualCron sends encrypted information across the default TCP port 16444. If you want to change this port you enter a new integer value here.

 

clip0126

 

Log settings tab

 

Extended debug logging

If you experience problems the VisualCron support may ask you to turn on extended debugging. When the support process is done you uncheck this option as it leverages the system.

 

Log to file - Client events

Controls if Client should write events to a file (placed in VisualCron X/log folder)

 

Log to file - Server events

Controls if Server should write events to a file (placed in VisualCron X/log folder)

 

If any Log to file option is activated, a log file will be created and entries will be written into the log file. A new log file is created for each day. If no Job has been run during a day (with logging on) - no file will be created. The server/client log file names are "log_serverYYYYMMDD.txt"/"log_remoteYYYYMMDD.txt". By default the log files are located in the "C:\Program Files\VisualCron\log\" folder.

 

Filters in log window

These settings control which type of events should be filtered out in the Show log window. These settings are the same settings as clicking on the icons in the main menu Information -> Show log window. When checking a box, the entries of that event type will not be shown. However, everything is still logged and unchecking that box will show those event types again.

 

clip0011

 

Output settings tab

Controls how Task output should be handled. By default VisualCron is only storing the first 3000 characters in the output. If you want to change this behavior then use the settings below.

 

clip0127

 

Language settings tab

Controls which language the Server should write in when writing entries in the log file.

 

Email settings tab

General email settings (for e.g. mail notification) are defined. If you have access to a SMTP server or gateway you can get email notifications from VisualCron with different kind of information for a specific Job.

 

clip0128

 

SMTP server

This can be an IP address or name of a server on Internet or local network.

 

Server port

Standard port is 25 but some ISP:s have blocked that port for outgoing and maybe incoming mail. Enter your port number here.

 

Server requires authentication

Check this box if you need to specify a username and password to send emails.

 

To email

By entering this field, your fields at Add Job, will be automatically entered. You can send to several emails at the same time by separating with a semicolon (";"). The To email address(es) shall be a valid email address(es) to where the email will be sent.

 

From email

By entering this field, your fields at Add Job, will be automatically entered. This is the default email that VisualCron uses to send email from.

 

From name

You can specify a name where your mail comes from. By default it is the server name.

 

Proxy tab

Controls what proxy settings you will use when you are using the Task type: HTTP. If you are unsure of the settings use Auto detect proxy or ask your administrator.

 

clip0129